SPECIFICATIONS FOR TYST ACOUSTIC WALL PANELS
This page provides clear and detailed specifications for TYST textile-covered acoustic wall panels, including acoustic performance, panel materials, dimensions, installation guidelines, maintenance recommendations, and fire reaction classification.

PRODUCTS
TYST is a textile covered acoustic panel created to meet your needs.
DATA SHEET
Download the TYST data sheet here:
HIGHLIGHTS
· Made to size
· High acoustic performance - class A
· Textiles of your choice
· Competitive pricing
· Fast installation
· Made in Denmark

ACOUSTIC PERFORMANCE
TYST panels use a glass wool core to ensure strong sound absorption.
For best acoustic results, we recommend 40 mm panels.
Download absorption reports:
Sound absorption report 40 mm
For advice on acoustic design, contact us.

DIMENSIONS AND SIZES
THICKNESS
-
20 mm or 40 mm
-
60, 80 and 100 mm are also possible upon request
MAXIMUM SIZE
-
Max length: 2400 mm
-
Max width: 1200 mm
Any size within these limits can be produced. For the best price, the following sizes are typically the most economical:
-
600 × 1200 mm
-
800 × 1200 mm
-
1200 × 1200 mm
-
1600 × 1200 mm
-
1800 × 1200 mm
-
2400 × 1200 mm

SUSTAINABILITY - EPD
TYST panels have a simple construction with no wood, steel, or aluminium frame, which helps reduce environmental impact.
Because of the high acoustic efficiency, fewer panels are often needed compared to many alternatives.
-
Mineral wool waste is recycled into new insulation
-
Textiles are recycled into new products (for example acoustic boards)
Downloads:
INSTALLATION
We recommend the following installation methods:
GLUE
The fastest and easiest method is gluing with construction adhesive.
A standard 300 ml cartridge covers approx. 1.25 m².
INSTALLATION BRACKETS
We supply different brackets for easy installation. Some are pre-installed at the factory, while others are mounted on-site.
See link to installation videos here:

REACTION TO FIRE
-
The mineral wool core is tested as non-combustible according to EN ISO 1182
-
Most TYST textiles are classified as B-s1, d0 according to EN ISO 13501-1
Always choose a textile with the correct classification for your project.
Download fire classification document (Danish):

CLEANING
-
Vacuum cleaning
-
Wipe with a heavily wrung-out cloth
HUMIDITY RESISTANCE
Suitable up to 90% RH.
Do not expose panels to condensation or water splashes.
FAQ – TYST Acoustic Panels
What is TYST made of?
TYST panels consist of a glass wool core covered with textile.
The construction is frameless, meaning no wood, steel, or aluminium is used.
How are the panels installed?
TYST Panels are mounted directly onto the wall. The installation method depends on the wall surface and panel type, and installation videos are available on the website.
Which thickness should I choose – 20 mm or 40 mm?
For most projects, we recommend 40 mm panels for the best sound absorption. 20 mm panels can be used where space is limited.
Are TYST panels fire rated?
The mineral wool core is classified as non-combustible according to EN ISO 1182. Most textiles are classified as
B-s1, d0 according to EN ISO 13501-1.
Can TYST panels be made to custom sizes?
Yes. TYST panels are produced to size within the maximum dimensions of 2400 × 1200 mm.
How do I clean the panels?
We recommend vacuum cleaning or wiping with a heavily wrung-out cloth.